Keypads for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| KI-HOA Keypad RTC (Supplied as standard*) The KI-HOA Keypad RTC provides Hand-Off-Auto control. The display presents up to four lines of real text with multilanguage translation, enhancing clarity and increasing ease of use. A battery operated real-time clock allows scheduling of run and off periods and adds accurate time stamping to diagnostics to aid rapid fault resolution. | | Remote HOA Keypad RTC Remote mountable keypad, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). The keypad offers Hand-Off-Auto control and can present up to four lines of real text with multi language translation, enhancing clarity and increasing ease of use. Battery operated real-time clock allows scheduling of run and off periods and adds accurate time stamping to logged events, aiding diagnostics. |
System Integration Modules – Communications for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| SI-POWERLINK Connects Unidrive, Commander, Digitax and the Pump Drive families to all POWERLINK networks. SI-POWERLINK serves applications ranging from simple open-loop systems through to those demanding precise motion control. The protocol is based upon standard Ethernet and provides a solution for real-time Industrial Ethernet to satisfy the requirements of industrial automation and process control. | | SI-PROFIBUS PROFIBUS interface module PROFIBUS-DP (Decentralized Peripheral) interface module enables follower connectivity. It is possible to use more than one SI-PROFIBUS or a combination of SI-PROFIBUS and other option modules to add additional functionality such as extended I/O, gateway functionality, or additional PLC features. |
| SI-DeviceNet DeviceNet networking system interface module enables follower connectivity. It is possible to use more than one SIDeviceNet or a combination of SI-DeviceNet and other option modules to provide additional functionality such as extended I/O, gateway functionality, or additional PLC features. | | SI-CANopen CANopen interface module supporting various profiles, including several drive profiles. |
| SI-Ethernet External Ethernet module that supports EtherNet/IP and Modbus TCP/IP and has an integrated web server that can generate emails. The module can be used to provide high speed drive access, global connectivity and integration with IT network technologies, such as wireless networking. To use multiple H300 drives in Multi-leader mode in a parallel HVAC system, each H300 drive must have an SI-Ethernet module fitted. | | SI-EtherCAT SI-EtherCAT allows the drive to connect and interface with EtherCAT networks. |
| SI-PROFINET SI-PROFINET allows the drive to communicate and interface with PROFINET PLCs and networks. | | |
System Integration Modules – Applications for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| MCi200 Second processor, providing advanced machine control using Machine Control Studio | | MCi210 Adds to the MCi200 with a dual port Ethernet interface directly on the processor and additional I/O |
System Integration Modules – Additional I/O for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| SI-I/O Extended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays | | |
Drive interface units – Back-up for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| Smartcard The optional Smartcard memory device can be used to back-up parameter sets, as well as copying them from one drive to another | | SD Card Adaptor Conversion device that allows an SD card to be inserted into the Smartcard slot, for parameter cloning and application programs |
Drive interface units – Communications for HVAC Drive H300 7.5kW 30A 200/240Vac 3PH
| KI-485 Adaptor This adaptor can be fit in place of the drive keypad and provides additional ports to communicate via RS485. The adaptor is commonly used for programming the drive. | | |
* Also requires an adaptor.