Description for Control Techniques Pump Drive F600 11kW 50A 200/240Vac 3PH
200-240Vac, 50A – 11kW Normal Duty Rating
Size 6 (391 H x 210 W x 227 D mm)
Energy savings, unlocking the potential
On average, 85% of a pump’s life-cycle cost is attributed to its energy consumption, therefore, optimising the energy usage can mean a significant reduction in the total cost of ownership. The F600 drive thrives on delivering more efficient ways of operating your variable torque application. You’ll see the benefits in reduced running costs and lower energy requirements.
Engineered for your application
The F600 Pump Drive offers a host of dedicated features including dry-run prevention, pipe fill, pump cleaning, over-cycling protection and level switch control. A range of different control modes covering single pumps and also different parallel pump configurations make Control Techniques’ F600 a truly versatile solution.
Free 5 year warranty
To share our confidence in the reliability of Control Techniques, drives in the F600 range are eligible for Control Techniques’ extended warranty, at no extra cost.
It is a testament to our exceptional track record for reliability, giving you total peace of mind that your investment is protected and your site will continue to run uninterrupted.
Warranty terms and conditions apply.
Features
Features for Control Techniques Pump Drive F600 11kW 50A 200/240Vac 3PH
Unmatched total cost of ownership
With innovative protective features and extended equipment life, the F600 has comprehensive pump and motor protection features which minimise unplanned downtime, improving overall effectiveness and guaranteeing better value for money. Bring true resilience to your application and easily ride-through component failures.
Automatic Error Recovery
In the unlikely event of detecting an error with your pump, the F600 has the ability to dynamically recover and resume normal operation.
Limit Protection
If the feedback exceeds the limits defined for your application, the F600 has the ability to raise an alarm or stop the drive to protect your equipment and preserve its lifetime.
Transducer Loss Protection
In the event of losing connection to the transducer, the F600 can stop, continue to run at a fixed speed or ignore the fault depending on the application requirements.
Fire mode
Fire mode allows the drive to disable all trips and to continue to run uninterrupted during emergency events if the application requires.
Sleep mode
When demand falls below a specified set-point the drive will automatically enter sleep mode and restart itself once demand rises above the set-point. Not only does this greatly reduce the amount of energy consumed, it also saves on equipment wear to preserve its lifetime.
Options
Options for Control Techniques Pump Drive F600 11kW 50A 200/240Vac 3PH
Keypads for Pump Drive 11kW 50A 200/240Vac 3PH
 | KI-HOA Keypad RTC (Supplied as standard*) The KI-HOA Keypad RTC provides Hand-Off-Auto control. The display presents up to four lines of real text with multilanguage translation, enhancing clarity and increasing ease of use. A battery operated real-time clock allows scheduling of run and off periods and adds accurate time stamping to diagnostics to aid rapid fault resolution. |  | Remote HOA Keypad RTC Remote mountable keypad, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). The keypad offers Hand-Off-Auto control and can present up to four lines of real text with multi language translation, enhancing clarity and increasing ease of use. Battery operated real-time clock allows scheduling of run and off periods and adds accurate time stamping to logged events, aiding diagnostics. |
System Integration Modules – Communications for Pump Drive F600 11kW 50A 200/240Vac 3PH
 | SI-POWERLINK Connects Unidrive, Commander, Digitax and the Pump Drive families to all POWERLINK networks. SI-POWERLINK serves applications ranging from simple open-loop systems through to those demanding precise motion control. The protocol is based upon standard Ethernet and provides a solution for real-time Industrial Ethernet to satisfy the requirements of industrial automation and process control. |  | SI-PROFIBUS PROFIBUS interface module PROFIBUS-DP (Decentralized Peripheral) interface module enables follower connectivity. It is possible to use more than one SI-PROFIBUS or a combination of SI-PROFIBUS and other option modules to add additional functionality such as extended I/O, gateway functionality, or additional PLC features. |
 | SI-DeviceNet DeviceNet networking system interface module enables follower connectivity. It is possible to use more than one SIDeviceNet or a combination of SI-DeviceNet and other option modules to provide additional functionality such as extended I/O, gateway functionality, or additional PLC features. |  | SI-CANopen CANopen interface module supporting various profiles, including several drive profiles. |
 | SI-Ethernet External Ethernet module that supports EtherNet/IP and Modbus TCP/IP and has an integrated web server that can generate emails. The module can be used to provide high speed drive access, global connectivity and integration with IT network technologies, such as wireless networking. To use multiple F600 drives in Multi-leader mode in a parallel pump system, each F600 drive must have an SI-Ethernet module fitted. |  | SI-EtherCAT SI-EtherCAT allows the drive to connect and interface with EtherCAT networks. |
 | SI-PROFINET SI-PROFINET allows the drive to communicate and interface with PROFINET PLCs and networks. | | |
System Integration Modules – Applications for Pump Drive F600 11kW 50A 200/240Vac 3PH
 | MCi200 Second processor, providing advanced machine control using Machine Control Studio |  | MCi210 Adds to the MCi200 with a dual port Ethernet interface directly on the processor and additional I/O |
System Integration Modules – Additional I/O for Pump Drive F600 11kW 50A 200/240Vac 3PH
 | SI-I/O Extended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays | | |
Drive interface units – Back-up for Pump Drive F600 11kW 50A 200/240Vac 3PH
 | Smartcard The optional Smartcard memory device can be used to back-up parameter sets, as well as copying them from one drive to another |  | SD Card Adaptor Conversion device that allows an SD card to be inserted into the Smartcard slot, for parameter cloning and application programs |
Drive interface units – Communications for Pump Drive F600 11kW 50A 200/240Vac 3PH
 | KI-485 Adaptor This adaptor can be fit in place of the drive keypad and provides additional ports to communicate via RS485. The adaptor is commonly used for programming the drive. | | |
* Also requires an adaptor.
Downloads
Downloads for Control Techniques Pump Drive F600 11kW 50A 200/240Vac 3PH
Pump Drive F600 Brochure
Pump Drive F600 Datasheet
Pump Drive F600 User-Guide